DONNEES D'ARRET SUR IMAGE
DONNEES D'ARRET SUR IMAGE (COMMANDE PLUG-IN)
L'ECU de commande de charge plug-in enregistre les informations relatives aux conditions de charge du véhicule et du plug-in sous forme de données d'arrêt sur image au moment où un DTC est enregistré.
Il peut être utilisé pour estimer ou reproduire les conditions dans lesquelles se trouvait le véhicule lors de l'apparition du dysfonctionnement.
Powertrain Plug-in Control
Affichage du tester |
---|
Vehicle Speed |
BATT Voltage |
Smoothed Value of BATT Voltage |
Total Distance Traveled |
Total Distance Traveled - Unit |
Inverter Water Pump Drive Request |
Radiator Fan Drive Request |
PISW Status |
My Room Operation |
DFR Drive Permission Signal |
HREL Drive Request |
ACRL Drive Request |
IGB Signal |
IGB ON Request |
IGCT Signal Status |
IGCT Keeping Request |
IG2 Signal Status |
Shift Position Information |
Charging Control Signal Status |
A/C Useable Power |
A/C Consumption Power |
Remote Air Control System |
Hybrid/EV Control System Control Mode |
Solar Available Information |
Solar Diagnosis Prohibition Notification |
Solar Charging Control Mode |
Solar Charging Permission Signal by Main CPU |
Solar Charging Boosting DC/DC Converter Voltage |
Solar Charging Boosting DC/DC Converter Input Power |
Solar Boosting DC/DC Converter Drive Request |
HV/EV Battery Total Voltage |
Charging Voltage for Hybrid/EV Battery |
Hybrid/EV Battery Local Bus Communication |
Hybrid/EV Battery Temperature when Charging Start |
Hybrid/EV Battery Maximum Temperature |
Hybrid/EV Battery Minimum Temperature |
Hybrid/EV Battery Charging and Power Feeding Permission Status with Hybrid/EV Battery Thermal Keep |
Hybrid/EV Battery Charging Power |
Hybrid/EV Battery Control Status on Thermal Keeping and Charging |
Hybrid/EV Battery Current for Driving Control |
Hybrid/EV Battery Current for Hybrid/EV Battery Control |
Auxiliary Battery Voltage Low Status |
Auxiliary Battery Voltage Low Status from Hybrid/EV |
Auxiliary Battery Voltage Low Status from Hybrid/EV Battery |
Hybrid/EV Communication Enable Information (Hybrid/EV Battery Local Bus) |
SOC of Immediately after Wake Up |
Charging Lid Switch Status |
Charging Lid Lamp Status |
Charging Lid Opening and Closing Status |
Hood Courtesy Switch Signal |
Charging Indicator lighting Request |
Charging Connector Connect Status |
Charging Connector Connect Status Voltage |
Charging Connector Lock Pin Status |
Charging Connector Lock Motor Unlock Direction Revolution Request Current |
Charging Connector Lock Motor Lock Direction Revolution Request Current |
AC Charging Positive Inlet Temperature Sensor Voltage |
AC Charging Negative Inlet Temperature Sensor Voltage |
AC Charging Positive Inlet Temperature |
AC Charging Negative Inlet Temperature |
AC Charging Inlet Connect Status |
DC Charging Inlet Temperature 1 |
DC Charging Inlet Temperature 2 |
DC Charging Inlet Temperature Sensor 1 Voltage |
DC Charging Inlet Temperature Sensor 2 Voltage |
Interlock Operation Status |
Charger Power Supply Voltage Type |
Charger Operation Status |
Charger Operation Request |
Charger Input Power |
Charger Output Power |
Charger Cooling Fan Drive Request |
Charger Drive Permission Signal |
AC Power Supply Rated Current |
AC Power Supply Rated Power |
Charging Control Information |
Charging History Information |
DC Operation Mode |
System Impedance Increase Abnormal |
Total Number of AC Charging |
AC Charging Total Time |
AC Charging |
AC Charging Operation Status |
AC Charging Input Minimum Voltage History |
DC Charging |
Target Charging Power |
Target Charging Power from Charger |
Charging Required Time Calculation Status |
Charging Required Time |
Charging Elapsed Time |
Charging State Elapsed Time |
AC Input Voltage for Monitoring |
AC Input Voltage Instantaneous Value 1 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 2 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 3 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 4 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 5 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 6 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 7 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 8 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 9 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 10 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 11 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 12 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 13 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 14 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 15 for Waveform Monitoring |
AC Input Voltage Instantaneous Value 16 for Waveform Monitoring |
Time Cycle of Charging Voltage Zero Crossing Point |
Plug-in Control ECU Voltage Request (SMP5) |
Plug-in Control ECU Voltage (VOMS5) |
Plug-in Control Module System Voltage (Plus) |
Plug-in Control Module System Voltage (Offset) |
Plug-in Control Module System Voltage (Minus) |
AC Input Current |
Charging Current Upper Limit |
Charging Current Duty from Charger |
Time Cycle of Charging Current Duty from Charger |
Charging Current Limit Status from Charger |
Charging Power Limit (Charging Voltage Low) |
DCV Sensor Voltage Status |
Timer Wait Request |
Sampling Power Supply Output Request (SP12) |
Sampling Power Supply Normal Status (SP12) |
Power Supply Voltage (SP12) |
PFC Boosting Circuit Driver Drive Status |
Voltage after Boosting by PFC Boosting Circuit |
Current after Boosting by PFC Boosting Circuit |
PFC Boosting Circuit Current Amplitude |
PFC Temperature |
High Voltage Circuit Shutdown Signal |
DC/DC Converter Operation Status |
DC/DC Converter Driver Drive Status (for Charging) |
Target DC/DC Converter Current (for Charging) |
DC/DC Converter Temperature (for Charging) |
Sub DC/DC Converter Operation Status (for Charging) |
Sub DC/DC Converter Drive Request (for Charging) |
Sub DC/DC Converter Operation Permission to Sub DC/DC Converter (for Charging) |
Sub DC/DC Converter Operation Permission from Outside (for Charging) |
Target Sub DC/DC Converter Voltage (for Charging) |
Target Sub DC/DC Converter Voltage from Outside (for Charging) |
Sub DC/DC Converter Output Voltage (for Charging) |
Sub DC/DC Converter Output Current (for Charging) |
Sub DC/DC Converter Constant Current Control (for Charging) |
Sub DC/DC Converter Temperature (for Charging) |
Sub DC/DC Converter Stop Request (for Charging) (Over Temperature) |
Sub DC/DC Converter Consumption Power (for Charging) |
Sub DC/DC Converter Start Request (for Charging) |
Single Phase/Three Phase Status |
AC Charging Negative Relay Status |
AC Charging Positive Relay Status |
AC Charging Negative Relay Drive Request |
AC Charging Positive Relay Drive Request |
AC Charging Precharge Relay Status |
AC Charging Precharge Relay Drive Request |
Charging Relay Connect Request in CCID Box from CCID Box |
Rush Current Prevention Resistance Relay Activate Request |
DCRB Connect Status |
DCRG Connect Status |
DCR Temperature Sensor 1 Voltage |
DCR Temperature Sensor 2 Voltage |
DCR Temperature 1 |
DCR Temperature 2 |
DCR Diagnosis Status |
DCR Stuck Closed Status |
SMRB Control Status |
SMRG Control Status |
Dysfonctionnement de la jauge SOC
DESCRIPTION Une jauge SOC a été adaptée sur ce véhicule. Dans ce circuit, l'ensemble de combiné d'instruments reçoit le signal d'affichage SOC en provenance de l'ensemble d'unité de convertisseur électrique via la communication CAN. L'ensemble de combiné d'instruments commande le fonctionne ...
Dysfonctionnement dans le circuit du capteur d'éclairage
DESCRIPTION
Le capteur de commande d'éclairage automatique détecte la luminosité ambiante. Le capteur crée un signal électrique sur la base de l'intensité de l'éclairage détectée et envoie un signal à l'ECU de carrosserie princip ...
Signal du capteur de vitesse de roue arrière droite bloquée en position basse
DESCRIPTION
Se reporter au DTC C051212.
Cliquer ici
N° de DTC
Objet de la détection
Condition de détection de DTC
...